Description
Description Organic vapour filter class A2 (high capacity). Material Plastic polypropylene. No metal parts. Usage Used against organic gas and vapour with a boiling point above +65°C ,such as solvents. The filter fits into the filter attachment of Sundstrom’s half and full face masks. An SR510 particle filter can be snapped onto the front of the filter. Two identical A1 filters can also be used with the SR500 PAPR by using filter adaptors. Size Largest diameter: 106 mm Weight 137 g Carbon The filter contains 100 g of activated carbon. Absorption capacity In tests with 5,000 ppm carbon tetrachloride at 30 l/min, the filter lasts for 45-50 minutes (standards requirements: >40 min) The filter absorbs approximately 42-45 g (1.5-1.6 oz) carbon tetrachloride (standards requirements: >38.4 g (>1.36 oz)) Storage Store at room temperature in clean, dry place. If seal has been broken, store away from contaminants in an air-tight container. Shelf life is 5 years if seal is unbroken. Expiry date printed on filter.
Thickness: 36 mm
Pressure drop
At 30 l/min: 25-30 Pa (standards requrement: <100 Pa)
At 95 l/min: 120-140 Pa (standards requirement: <400 Pa)